Daily Maintenance

Loading Tools and Setting Tool Life Counters

Insert burs into the 12-position magazine in the right order, run automatic length measurement and configure tool-life counters per material.

6 min 30 s · Reviewed by CAMDENT technical support

Step by step

  1. 1
    Open the magazine and identify the position for each tool number
  2. 2
    Insert each bur into the position defined in the CAM tool table
  3. 3
    Confirm every bur is fully seated and moves freely in its holder
  4. 4
    Run the automatic tool-length measurement for all positions
  5. 5
    Enter the tool-life counter per material in the controller

These guides summarise the standard workflow. Always follow the manual shipped with your machine, and confirm material parameters with CAMDENT technical support before running a material for the first time.