CAD/CAM Bur Selection: Machine Compatibility and Material Matching
A bur is not a consumable you pick by price. It has to match the shank interface of your machine, the abrasiveness of the material, and the tolerance your CAM strategy assumes. This page is the compatibility matrix we use when a lab asks us which bur to run.
Labs usually discover a bur problem after the fact: a margin chips, a crown comes out undersized, or the spindle starts loading harder than it used to. Almost always the cause sits in one of three places — the wrong bur line for the machine, the wrong edge geometry for the material, or a bur that is simply worn out.
The matrix on this page is generated directly from the bur lines CAMDENT stocks, so it cannot drift out of date. Below it, the material and wear sections explain what the matrix does not: why two burs that both fit the same machine behave very differently on zirconia and on titanium.
Start with the shank interface, not the price
Every dental mill defines a tool interface: the shank diameter, the insertion length, and the way the holder clamps the bur. A bur that physically fits but sits at the wrong depth will be measured as the wrong length by the tool probe, and every job after that will cut at the wrong Z height.
This is why bur lines are sold per machine family rather than as one universal part. The table below lists every bur line we stock against the machine family it is specified for. If your machine is not listed, the shank interface is the first thing to confirm before ordering — send us the machine model and we will tell you which line fits.
Compatibility matrix
Rows are generated from the current CAMDENT bur catalogue. The materials column lists what the line is intended to cut, not every material the machine itself can handle — those are two different questions, and the second one is answered on the material compatibility page.
| Dòng mũi phay | Dùng cho | Vật liệu | |
|---|---|---|---|
| AIM CAD/CAM Burs | AIM dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| ARUM CAD/CAM Burs | ARUM dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Gilbach CAD/CAM Burs | Gilbach dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Imes-icore 250i CAD/CAM Burs | Imes-icore 250i dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Imes-icore 350 CAD/CAM Burs | Imes-icore 350 dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Roland CAD/CAM Burs | Roland dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Sinord MCX5 CAD/CAM Burs | Sinord MCX5 dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Titanium CAD/CAM Burs | Titanium dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| VHF CAD/CAM Burs | VHF dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Zirconia CAD/CAM Burs | Zirconia dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
| Zirconia CAD/CAM Burs - Ø6mm | Zirconia dental milling machines | Zirconia, PMMA, Wax, Composite resin | Xem |
Matching the edge to the material
Two burs can share the same shank and still be wrong for each other's job. The differences that matter are the cutting edge geometry, the coating, and how the tool behaves as it wears.
- Zirconia is hard and abrasive, and milling it produces a fine dust that dulls an edge quickly. Zirconia lines use a geometry that keeps cutting rather than rubbing once the edge starts to go, because a rubbing bur transfers heat into the green blank and can leave a glazed, chipped margin.
- Titanium and CoCr are ductile. They need a sharper, more positive edge and they generate heat in the cut, which is why titanium work is a wet-milling operation on machines configured with a coolant circuit. Running a zirconia bur in titanium is a common and expensive mistake: the edge geometry is wrong and the tool life collapses.
- PMMA, wax and composite are soft and dimensionally forgiving. Almost any sharp bur will cut them, so the limiting factor is usually surface finish and chip evacuation rather than edge wear — a bur that is too fine loads up with molten acrylic instead of cutting it.
- Glass ceramic is brittle and unforgiving of vibration. It is milled with dedicated diamond-coated tooling and, on our machines, in the wet configuration.
Diameter is a detail decision, not a quality decision
A larger bur removes material faster and deflects less, which is why roughing is done with the biggest tool the anatomy allows. A smaller bur reaches into occlusal detail and interproximal contacts, but it is more flexible and leaves a finer step-over pattern.
The practical rule is to rough with the largest tool your strategy can use and finish with the smallest tool that still leaves an acceptable surface, rather than finishing everything with one small bur. Using a single small bur for the whole job is the most common reason a 30-minute crown takes two hours.
CAMDENT stocks zirconia burs in both shank diameters used across the machine families we support. Confirm the diameter against your machine's tool holder before ordering: the two are not interchangeable.
Wear signals: change the bur before the part fails
A worn bur rarely announces itself. It degrades the cut gradually, and by the time the part is visibly wrong you have usually already sintered it. These are the signals worth watching, in the order they normally appear.
- 1Listen to the cut
A sharp bur has a steady, clean cutting note. A dulling bur develops a higher-pitched whistle or a rhythmic load as the edges rub instead of cutting.
- 2Watch the spindle load trend
If the same program on the same material starts drawing noticeably more spindle load than it did when the bur was new, the edge has gone.
- 3Inspect the green part
Chipping on thin margins, a fuzzy or torn surface, and white burn marks at the entry point are all signs of a rubbing edge.
- 4Measure the fit
A drifting marginal fit that cannot be explained by the sintering curve usually means the bur is deflecting and cutting undersized.
- 5Track the count, do not guess it
Use the controller's tool-life counter per material. It is a far more reliable trigger than waiting for a visible defect, because it changes the bur before the defect exists.
Tool-life counters are only meaningful if they are set per material. Zirconia and PMMA wear the same bur at completely different rates, so one shared counter will either waste burs or break parts.
Handling and storage
Carbide edges are brittle. Most 'premature' bur failures we see are handling damage, not wear: burs rolling against each other in a drawer, a bur dropped on the bench, or a bur stored loose in a tool tray with swarf in it.
Keep burs in their individual sleeves, keep the sleeves closed, and never clean a bur by knocking it against the machine frame. Wipe the shank with a lint-free cloth before it goes into the holder — swarf on the shank is read by the tool probe as part of the tool length.
Câu hỏi thường gặp